Toshiba Aquilion 4
- System Components Include:
7.5MHU MegaCoolTM X-RAY TUBE
4 SLICE SOLID-STATE DETECTOR ARRAY
47CM WIDE, METAL-FREE COUCH TOP
72 CM GANTRY APERTURE
+/- 30 DEGREE GANTRY TILT
OPERATOR’S CONSOLE WITH TWO 32-BIT PROCESSORS
TRUE MULTI-TASKING SYSTEM – SCANNING, RETRIEVING,
• RECONSTRUCTING, ARCIVING AND FILMING SIMULTANEOUSLY
60KW GENERATOR, FOR HIGH POWER UP TO 500MA
80, 100, 120, & 135KV SELECTIONS
SUB-SECOND SCANNING (0.5 SEC. SCAN TIME )
HIGH CONTRAST RESOLUTION OF 0.35MM
REAL EC REDUCES PATIENT DOSE UP TO 40%
SURE TECHNOLOGIES TO OPTIMIZE X-RAY USAGE
SURE START BOLUS TRACKING DEVICE
VOLUME IMAGE PROCESSOR
FAST RECONSTRUCTION TIME UP TO 12 FRAMES/SECOND FOR
• ANATOMY VISUALIZATION
RASP - RASTER ARTIFACT SUPPRESSION PROTOCOL
APMC – AUTOMATIC PATIENT MOTION CORRECTION
BHC – BEAM HARDENING CORRECTION
MULTI VIEW – FOR MULTI-PLANAR RECONSTRUCT
TWO HIGH COLOR, HIGH CONTRAST 19” FLAT PANEL LCD MONITORS
G.E. LIGHTSPEED PLUS QUAD CT SCANNER (2001)
- - H2 Gantry
- - 6.5MHU X-Ray Tube ……… Dunlee
- - Operators Console
- - Computer System
- - Installed Options
- - VariViewer
- - AutomA
- - Power 440
- - Thin Twin Helical
- - Helical Tilt
- - Recon Plus
- - Smart Speed
- - Connect Pro
- - Smartscore Pro
- - Tube last Changed 09/08/07 …… Current mas 37,000,000
- - Available: Oct 1st
Philips Brilliance 40 Mobile CT System
- 2006 Date of Manufacture
- 40 slice Simultaneous Acquisition.
- MRC 8 MHU X-ray tube (low usage)
- 60kW HF generator
- Brilliance Workspace CT User Environment with Dual Flat panel monitor console.
- System SW Options included: CD Writer, Rate Responsive CV Toolkit with 0.4 sec. rotation, DoseRight Cardiac,
Retro & Prospective Gating, ECG monitor, COBRA Cardiac Recon., and DICOM Work-list.
- Housed in an AK Medical trailer.
2004 Aquilion 64 Slice CT Scanner
- Vitrea C1 Software Package, Workstation for Vitrea System
- Console Desk, Image Maker Kit
- Power Conditioner/ Distributor 125 KVA Universal
- CT Accessory Kitâ Long Couch 1800mm
- DVD Ram drive, LCD Monitor, ECG scan prospective for AQ/MP
- ECG Reconstruction AQ/MP, 400 m-sec gantry rotation, Dicom Modality Checklist
- SURE Technology with Cardio
- LOCATED IN THE SOUTH
GE LightSpeed 16 Slice CT Scanner
- Still in use
- Very Good Condition
- Under GE Service
- January 2005 year
- Hercules Tube
- Tube Last Replaced June 20, 2007
- Gantry Rotations 618,396
- Tube mAs 112348584
- Software Options:
- SmartPrep
- SmartSpeed
- Helical Tilt
- Autom A
- VariViewer
- Patient – 16 – Slice
- 3000 Image Series
- ConnectPro
- Direct 3-D
- SmartPrep
- Card IQ SnapShot
- SmartScore Pro
- Available in Feb
GE LightSpeed QX/i Four Slice CT
- Still in Use
- Very Good Condition
- Under GE Service
- October 1999
- Flat Panel Monitors (MultiSync LCD 1880SX Monitors)
- New Tube March 4, 2008
- Tube Usage (Patient 230, 122, Non-Patient 8210)
- Total System Scan Seconds 1392506.8
- Software Options:
- Reformat
- ConnectPro
- SmartScore Pro
- Smart Prep
2002 GE Lightspeed Qxi H2
- Reformat
- Thin twin helical
- Helical tilt
- Smart score
- Auto ma
- power 440 max
- veri viewer
- smart prep
- connect pro
- august 2007 tube w/104 million mas
- gantry h2 7,771,720 rotations
- located in mo
- Available Mid Oct
GE Lightspeed QXI 4 slice CT Scanner
This system is available now, de-installed and located in California. You can inspect anytime.
- H1 Gantry
- S/N RH24383
- made in 1999
- 0.8 second rotation
- 2 year old tube (24 months of usage on the tube) facility averaged approximate 15-20 patients per day.
- 53 KW Generator,
- Software level H1.3M4
GE Lightspeed QXI 4 slice CT Scanner, H1 gantry
- December 1998, Serial Number on
- gantry tag; 235223CN5, Table s/n 234661CN7,
- Tube replaced July 6, 2007 (Mas 19,285,849) Low usage on the tube.
- Has: Smart Prep, Connect Pro, Reformat,
- Dual Flat Screen Monitors (1) 55007590YA (2) 550006792YA